Teledyne Leeman M-8000


The J.J. Wilbur Company is proud to offer the Teledyne Leeman Labs QuickTrace® M-8000 Mercury analyzer. The QuickTrace® M-8000 Cold Vapor Atomic Fluorescence (CVAF) Mercury Analyzer is ideal for ultra-trace to sub-mg/L mercury quantitation. It easily achieves the ultra-trace mercury detection limit of < 0.05 ng/L demanded by customers employing EPA method 1631. The QuickTrace® M-8000 is also versatile enough to analyze samples > 400 μg/L in a research or industrial setting without dilution.

Depending on your laboratory's requirements, the QuickTrace® M-8000 mercury analyzer supports three modes of operation:

Mode 1: Cold Vapor Atomic Fluorescence Spectroscopy (CVAFS)

Mode 2: Cold Vapor Atomic Fluorescence Spectroscopy Single Gold Trap Amalgamation (CVAFS-SGTA)

Mode 3: Cold Vapor Atomic Fluorescence Spectroscopy Double Gold Trap Amalgamation (CVAFS-DGTA)

The mode can be changed in software, without hardware or tubing configuration changes. These innovative features save you set up time and eliminate costly mistakes.

The QuickTrace® M-8000 also employs cost saving features during the gold trap desorption such as shutting down the flowing rinse and slowing the SnCl2 flow. These innovative features can save the laboratory thousands of dollars per year by reducing reagent and waste costs.

Using the proven cold vapor atomic fluorescence (CVAF) technique combined with multi-tasking Windows® based QuickTrace® software package, the QuickTrace® M-8000 is one of the most stable reliable fluorescence analyzer available today.

For ultra-trace analysis we recommend our autosampler enclosure to protect the samples from determinate errors such as dust particles. The enclosure will also protect your investment from the harsh acid gases normally present in and around digested samples.


Applications



Product Benefits


  • Ultra-trace detection limits (< 0.05 ng/L IDL)

  • Linearity greater than 4 orders of magnitude

  • Dynamic range < 0.05 ng/L to > 400 μg/L

  • In Mode 1 by response comparison to a 100 ng/L standard, the system exhibits < 0.01% memory effect of a 1 mg/L standard immediately following the ingestion of a 1 part per million (mg/L) sample.

  • In Mode 1 without employing our smart rinse technology the system is ready to accurately measure a sample within four minutes following the ingestion of a 1 ppm sample

  • Mode 2 & 3 - Short term precision (%RSD @ 95% Confidence) = 2.5% @ 5 ng/L, n=5​

  • Non-foaming Gas Liquid Separator (GLS) with overflow prevention system

  • Automatic end of run and inactivity standby routines

  • ≤ 0.05 ng/L instrument detection limits

  • Advanced contamination control, over range and smart rinse features

  • Intuitive gas controls eliminating air infusion into the system during sample probe movements during mode 2 and 3 analysis

  • EPA 1631 and EPA 245.7 compliant (gold amalgamation modes)

  • “Smart Rack” technology

  • 12-roller 4-channel peristalic pump

  • Sample volume 0.5 mL to > 50 mL

  • Unlimited QC sample positions